Extended Electrode Cable Variants
The extended electrode cables are designed for users of Starstim 32 and Starstim 20 systems whose intended montage or setup cannot be realized with the standard set of cables.
The cables are offered in two lengths: 0.35 m and 1.2 m.
Depending on the variant chosen, the labeling at the electrode clips of each cable reflects either channel number and default position, or just channel number.
Product information
The 10 Electrode Cable is designed for custom montages with our 8-channel systems: Starstim 8, Starstim tES, and Enobio 8. Of the10 electrode clips, 8 have a numerical annotation (from 1-8) of the channel that corresponds to the custom montage designed in the software. The 2 remaining are meant for reference electrodes CMS-DRL and are annotated as such. The 10 Electrode Cable is included with the Starstim 8, Starstim tES, and Enobio 8 systems. For users whose intended montage or setup requires a longer distance between the device and the electrodes, a long 10 Electrode Cable is available.
Technical specifications
Extended Cables for Starstim 32
· Length: 0.35 m (between device input and electrode connector overmolds)
· Variants labelled with channel number and default position:
· Cable 1 [NE017-S32-E.1PC]: (Channel 01-08) P8,T8,CP6,FC6,F8,F4,C4,P4
· Cable 2 [NE017-S32-E.2PC]: (Channel 09-16) AF4,Fp2,Fp1,AF3,Fz,FC2,Cz,CP2
· Cable 3 [NE017-S32-E.3PC]: (Channel 17-24) PO3,O1,Oz,O2,PO4,Pz,Cp1,FC1
· Cable 4 [NE017-S32-E.4PC]: (Channel 25-32) P3,C3,F3,F7,FC5,CP5,T7,P7
· Variants labelled with channel number only:
· Cable 1 [NE017-S32-E.1C]: (Channel 01-08)
· Cable 2 [NE017-S32-E.2C]: (Channel 09-16)
· Cable 3 [NE017-S32-E.3C]: (Channel 17-24)
· Cable 4 [NE017-S32-E.4C]: (Channel 25-32)
Long Cables for Starstim 32
· Length: 1.2 m (between device input and electrode connector overmolds)
· Variants labelled with channel number and default position:
· Cable 1 [NE017-S32-L.1PC]: (Channel 01-08) P8,T8,CP6,FC6,F8,F4,C4,P4
· Cable 2 [NE017-S32-L.2PC]: (Channel 09-16) AF4,Fp2,Fp1,AF3,Fz,FC2,Cz,CP2
· Cable 3 [NE017-S32-L.3PC]: (Channel 17-24) PO3,O1,Oz,O2,PO4,Pz,Cp1,FC1
· Cable 4 [NE017-S32-L.4PC]: (Channel 25-32) P3,C3,F3,F7,FC5,CP5,T7,P7
· Variants labelled with channel number only:
· Cable 1 [NE017-S32-L.1C]: (Channel 01-08)
· Cable 2 [NE017-S32-L.2C]: (Channel 09-16)
· Cable 3 [NE017-S32-L.3C]: (Channel 17-24)
· Cable 4 [NE017-S32-L.4C]: (Channel 25-32)
Extended Cables for Starstim 20
· Length: 0.35 m (between device input and electrode connector overmolds)
· Variants labelled with channel number and default position:
· Cable 1 [NE017-S20-E.1PC]: (Channel 01-06) P8,T8,F8,F4,C4,P4
· Cable 2 [NE017-S20-E.2PC]: (Channel 07-10) Fp2,Fp1,Fz,Cz
· Cable 3 [NE017-S20-E.3PC]: (Channel 11-14) O1,Oz,O2,Pz
· Cable 4 [NE017-S20-E.4PC]: (Channel 15-20) P3,C3,F3,F7,T7,P7
· Variants labelled with channel number only:
· Cable 1 [NE017-S20-E.1C]: (Channel 01-06)
· Cable 2 [NE017-S20-E.2C]: (Channel 07-10)
· Cable 3 [NE017-S20-E.3C]: (Channel 11-14)
· Cable 4 [NE017-S20-E.4C]: (Channel 15-20)
Long Cables for Starstim 20
· Length: 1.2 m (between device input and electrode connector overmolds)
· Variants labelled with channel number and default position:
· Cable 1 [NE017-S20-L.1PC]: (Channel 01-06) P8,T8,F8,F4,C4,P4
· Cable 2 [NE017-S20-L.2PC]: (Channel 07-10) Fp2,Fp1,Fz,Cz
· Cable 3 [NE017-S20-L.3PC]: (Channel 11-14) O1,Oz,O2,Pz
· Cable 4 [NE017-S20-L.4PC]: (Channel 15-20) P3,C3,F3,F7,T7,P7
· Variants labelled with channel number only:
· Cable 1 [NE017-S20-L.1C]: (Channel 01-06)
· Cable 2 [NE017-S20-L.2C]: (Channel 07-10)
· Cable 3 [NE017-S20-L.3C]: (Channel 11-14)
· Cable 4 [NE017-S20-L.4C]: (Channel 15-20)
Choose your system
The best in class wearable and wireless 32-channel system with tES stimulation and EEG monitoring capabilities
Wearable and wireless 20-channel system for targeted multi-channel tES stimulation and precise simultaneous EEG monitoring
Wearable wireless 8-channel system for targeted multi-channel tES stimulation and precise simultaneous EEG monitoring
End-to-end system for remotely supervised home-based multi-channel tES clinical investigations